Product Information

Product Notice - January 23, 2018

THESE PRODUCTS  NOT RECOMMENDED FOR NEW APPLICATIONS:

  • RCT-100  AC Repeat Cycle Timer, 117VAC
  • RCT-100A  AC Repeat Cycle Timer, 234VAC
  • RCT-100B  AC Repeat Cycle Timer, 24VAC

Click here for Datasheet: 800-96A PDF Product Notice - January 23, 2018 - Product Information - Peaktronics - pdf-icon
 

REPLACEMENT PRODUCT:

  • RCT-101  AC Repeat Cycle Timer, 117VAC
  • RCT-101A  AC Repeat Cycle Timer, 234VAC
  • RCT-101A  AC Repeat Cycle Timer, 24VAC

Click here for Datasheet: 800-205A PDF Product Notice - January 23, 2018 - Product Information - Peaktronics - pdf-icon

 

Replacing RCT-100x with RCT-101x (refer to Datasheets for complete details)

 

MECHANICAL

The RCT-100x has two mounting tabs to mount the unit to a bracket or other suitable surfaces inside the actuator.  The RCT-101x has mounting slots that match the mounting footprint of the RCT-100x.  However, the different mechanical configuration of the RCT-101x makes is slightly larger; this may require relocating the RCT-101x - refer to the datasheets for dimensional details.  Alternatively, the RCT-101x can be mounted to the side of the actuator's motor using the two high-strenghth high-temperature tie wraps included with the unit..

ELECTRICAL

The RCT-100x and RCT-101x use the same electrical connections (POWER & LOAD) and are directly compatible.  RCT-101x units are designed with a lower leakage current to prevent powering an electrical brake when the actuator motor is turned off.  Applications using the special low leakage RCT-100V unit can use the RCT-101 to replace it.

FUNCTIONAL

The RCT-100x and RCT-101x have adjustable "ON" and "OFF" time settings.  Both units have an "OFF" time setting that ranges from 0.5 to 10 seconds.  However, the RCT-100x has an "ON" time setting that ranges from 0.1 to 2 seconds, while the RCT-101x has a range of 0.1 to 1 second.  An "ON" setting greater than 1 second is no longer available.